+ DNA STR / INTERPRETATION & REVIEW
DNA STR interpretation.
A connected examination record.
From the electropherogram to the documented assessment. Inspect the signal, record interpretations and uncertainty, and preserve the basis of comparison, evaluation and independent review.
01 / SOURCE SIGNAL & IMPORTED ANALYSIS
Inspect the signal. Keep its analysis in context.
Read detector channels in the native scan frame, then inspect separately imported locus, allele, size and height values. The source signal and the analysis supplied with it remain identifiable throughout the examination.
- Channel visibility, scan selection and interval observations
- Original signal values and source-specific coordinates
- Imported peak designations retained as supplied analysis
These PROVEDIt captures show raw detector data on a scan axis. Imported base-pair sizes do not create a continuous base-pair mapping for the native trace.
02 / CONTEMPORANEOUS INTERPRETATION
Record what you observe—and what remains uncertain.
Link an observation to a native signal sample, an interval or an imported peak. Record the interpretation, possible artifact, contributor assessment and uncertainty with typed notes or spoken commentary.
An imported designation, an examiner’s interpretation and a later revision remain distinct contributions. A peak with no supplied scan position is not placed on the native trace by inference.
03 / INTERPRETATION BEFORE COMPARISON
Preserve interpretation before comparison.
Submit Analysis before opening the reference. Retain that independent record as comparison develops, including when reference material was opened and which observations support a similarity, difference or unresolved question.
- A fixed Analysis submission
- Recorded reference opening
- Comparative observations with source citations
04 / PROPOSITIONS & STATISTICAL BASIS
State the propositions and statistical basis.
Document the propositions being considered, contributor assumptions, limitations and the observations supporting the evaluation. Record whether statistical evaluation was not performed or supplied externally, retaining the associated report and its provenance.
PROFAS provides the examination and review record. It does not calculate mixture likelihood ratios or replace the laboratory’s statistical interpretation method.
05 / INDEPENDENT VERIFICATION
Independent work. A reviewable conclusion.
Retain the verifier’s eligible independent baseline before target findings are disclosed. Link subsequent review to the exact submitted examination, cited observations and supplied reports, keeping the baseline and post-disclosure account distinguishable.
- Independent baseline before access to target findings
- Recorded release and opening of the target
- Cited review with the earlier work retained
06 / RESEARCH & TEACHING
Explore how interpretations differ.
The aim is to make differences in peak interpretation, artifact hypotheses, contributor assessments and explanation available for study. Educators can use separate attempts and source-specific feedback to discuss how an interpretation develops.
07 / MATERIAL & SCOPE
Define the material. Discuss the study.
The current module demonstrates selected plain numeric FSA signal data and separately imported STR peak tables using PROVEDIt research material. Source formats and analysis outputs are checked against the supported import scope. Reference identity, assumptions and review conditions belong in the study or laboratory protocol.
The screenshots use published research samples from PROVEDIt, described by Alfonse and colleagues. They illustrate the interface and recording workflow; they do not present a casework conclusion.
LET'S DEFINE THE NEXT QUESTION
Explore DNA STR with PROFAS.
A research question, a teaching exercise or a comparative examination workflow. Start with the intended use.
Discuss a project